RY-ZW UV Light Intensity Meter For 280-400nm 0-400mW/m2 Ultraviolet Radiation RS485 Solar UV Sensor

RY-ZW UV Light Intensity Meter For 280-400nm 0-400mW/m2 Ultraviolet Radiation RS485 Solar UV Sensor

Details
UV radiometer is a precise instrument used to measure the ultraviolet radiation of the sun (UVAB wavelength range) in the atmosphere. The instrument can be used with data collector to provide information of public concern: UV index, UV erythema measurement, UV effect on human body and UV special biological and chemical effects. Therefore, it has been paid more attention in meteorology, industry, architecture and medicine. It is widely used in the study of erythema dose caused by exposure, comprehensive environmental ecological effect, climate change and ultraviolet monitoring and prediction.
Category
Solar Sensors
Share to
Send Inquiry
Description
Technical Parameters

Spectral Range

UVAB 280~400nm;

Cosine Response

≤4%(When the solar altitude angle is 30 degrees)

Working Temperature

-50℃~+50℃

Measuring Range

0~70 w/m-2 / UV index 0-15

Response Time

≤1s(99% response)

Output

RS485

 

INSTALLATION & MAINTENANCE

The installation site of the UV radiation sensor shall be selected to be free of any obstacles above the sensing element plane, so as to ensure that there are no obstacles with an altitude angle of more than 5 ° in the direction of sunrise and sunset, and the phenomenon of shadow falling on the sensing surface shall be avoided. If it is placed in the box, pay attention to the surrounding reflected light, and it should not be close to the heat source.

During installation, adjust the small bubble of the level to the middle position, and then fix it.

The connecting cable between the UV radiation meter and the recorder shall be double core shielded wire, and the connection mode of the UV external plug is: 1 is signal +, 2 is signal -. And it has waterproof performance. Cables shall be firmly fixed on supports or buried underground for protection.

If it is measured with a digital voltmeter, the measured voltage divided by the sensitivity coefficient of the purple surface is the radiation amount.

Radiation = measured MV * 1000 / sensitivity coefficient = w / m2

The purple surface of continuous work shall be inspected at least once a day, mainly to see whether the glass cover is clean, and if there is ice, snow, frost, dew, etc., try to gently remove these deposits. In addition, the level should be checked regularly.

Storage conditions:

Indoor with relative humidity less than 80% and free of corrosive and volatile substances

If you are interested in our products, please click here to go to the homepage and to contact us.

 

 

 

 

Hot Tags: ry-zw uv light intensity meter for 280-400nm 0-400mw/m2 ultraviolet radiation rs485 solar uv sensor, China, manufacturers, suppliers, factory, price, cost, best, for sale, 0 20mv Voltage Signal Solar Radiation Sensor, Solar Radiation Sensor, Total Solar Radiation Sensor, Solar Radiation Sensors, Total Radiation Sensor Product 0 20mv, Photosynthetically Active Radiation Sensor