Parameters |
Measuring Range |
Accuracy |
Resolution |
Sampling Frequency |
|
Ambient Temperature |
-40-60℃ |
±0.3℃@25℃ |
0.01℃ |
1HZ |
|
Relative Humidity |
0-100%RH |
±3%RH (10%-80%RH, No Condensation) |
0.01%RH |
1HZ |
|
Wind Speed |
0-60m/s |
±(0.3+0.03V)m/s;V≤30m/s ±(0.3+0.05V)m/s; V≥30m/s (V stands for standard wind speed in a wind tunnel) |
0.01m/s |
10HZ
|
|
Wind Direction |
0-359.9° |
±3° (when Wind Speed <10m/s) |
0.1° |
10HZ
|
|
Atmospheric Pressure |
500-1100hPa |
±0.5hPa(25℃,950-1100hPa) |
0.1hPa |
1HZ |
|
PM2.5 |
0-500ug/m³ (Extensible 1000ug/m³) |
±(10+10%)ug/m³ |
1ug/m³ |
1HZ |
|
PM10 |
0-500ug/m³ (Extensible 1000ug/m³) |
±(10+10%)ug/m³ |
1ug/m³ |
1HZ |
|
CO |
0-10ppm |
±5%FS |
1ppb |
1HZ |
|
NO2 |
0-5ppm |
±5%FS |
1ppb |
1HZ |
|
SO2 |
0-5ppm |
±5%FS |
1ppb |
1HZ |
|
O3 |
0-5ppm |
±5%FS |
1ppb |
1HZ |
|
H2S |
0-2ppm |
±5%FS |
1ppb |
1HZ |
|
TVOC |
0-10ppm |
±5%FS |
1ppb |
1HZ |
|
Operating Temperature |
-30℃~70℃ |
|||
|
Output |
Standard product with RS485 interface, ModbusRTU; Customizable option SDI-12(Extra costs apply) |
|||
|
Maximum Output Frequency |
Passive Mode: 1/S Active Mode: 1/min |
|||
|
Power Supply |
DC9-24V |
|||
|
Level of Protection |
IP65 |
|||

If you are interested in our products, please click here to go to the homepage and to contact us.
Hot Tags: xf1013 outdoor air quality monitor pm2.5 pm10 co no2 so2 o3 h2s tvoc sensor wind speed and direction sensors, China, manufacturers, suppliers, factory, price, cost, best, for sale, Outdoor Ammonia NH3 Sensor, Professional grade weather station, Tipping Bucket Rain Gauge Pulse Output 0 2mm, Economical Ultrasonic Wind Speed Direction Sensor Ultrasonic Anemometer RS485, Compact all in one weather sensor, LUX Luxmeter or illuminance sensor